Copper Price 11/17/2025 5.01050

CONTROL AND LIGHTING SYSTEMS

Found 32 products.
View as Grid List Table
Sort by
Display per page

16 AWG 2 conductor 65 strands bare copper conductors with PVC/NYLON insulation, unshielded and an overall PVC jacket. UL TC 600V 90’C DRY or CL3/CM Lighting and control cable for Vantage station devices and touch screens

18 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I 90°C applications. For Vantage Control Panels

18 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I 90°C applications. For Vantage Control Panels

22 AWG 2 conductor 7 strand bare copper with polyvinylchloride insulation, unshielded with an overall PVC jacket. (UL) CL3R Sun Res or CM C(UL)US 75°C, for Lutron Vareo Systems

Two element composite cable with an overall PVC jacket. (UL) CL3R or CMR c(UL)us 75’C 300V, for AMX AX-LINK Network and Automation Control Cable

24AWG 2C 7XTC OAS/BRD FPE/TPE BLK

24 AWG 4 conductors 7 strand tinned copper, foamed PP insulation, an aluminum/Mylar shield, a tinned copper drain wire, a tinned copper braid shield and an overall matte finish TPE jacket for remote of permanent installations of DMX512 lighting control applications. Made in USA

22 AWG 1 pairs cable constructed with stranded tinned copper, foam PP insulation, an aluminum/Mylar shield, a stranded drain wire, a tinned copper braid shield and an overall PVC jacket. (UL) CMR C(UL)US or AWM 2919 30V 80°C FT-1

22 AWG 2 pairs cable constructed with stranded tinned copper, foam PP insulation, an aluminum/Mylar shield, a stranded drain wire, a tinned copper braid shield and an overall PVC jacket. (UL) CM C(UL)US or AWM 2919 30V 80°C FT-1

Three element composite cable, elements pulled in parallel with an overall PVC jacket. (UL) CL3R or CMR c(UL)us 75°C, automation control cable for systems

Five element composite cable, 1 pair 22 AWG shielded, 2 conductors 18 AWG unshielded, 4 Category 5E components with an overall PVC jacket for data communications and security applications manufactured in the USA and listed (UL) CM, 75°C.

Two element composite cable, elements pulled in parallel with an overall PVC jacket. (UL) CL3R or CMR c(UL)us 75°C, automation control cable systems

ProductAWG Size & StrandingConductor CountJacket ThicknessCable ODCable Weight
AV162VANT-07/04* -2 Conductors---
AV182LUT-44/10** 18 AWG, Class B 7 Strand2 Conductors0.045”0.262”40 lbs/Mft
AV184LUT-44/09** 18 AWG, Class B 7 Strand4 Conductors0.045”0.313”64 lbs/Mft
AV222LUT-44/03 -2 Conductors0.027"0.174”16 lbs/Mft
AVAXLINK-00 -----
AVB24DMX2C --0.040”0.240” ± 0.010”37 Lbs/Mft
AVB24DMX4C --0.040” Pressure0.270” ± 0.010”45 lbs/Mft
AVBDMX2C --0.035”0.257” ± 0.010”40 lbs/Mft
AVBDMX4C --0.035”0.270” ± 0.010”47 lbs/Mft
AVCRESCDM6B-60/2 -----
AVCRESCQ-60/09 -----
AVCRESCT-60/02 -----