16 AWG 2 conductor 65 strands bare copper conductors with PVC/NYLON insulation, unshielded and an overall PVC jacket. UL TC 600V 90’C DRY or CL3/CM Lighting and control cable for Vantage station devices and touch screens
18 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I 90°C applications. For Vantage Control Panels
18 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I 90°C applications. For Vantage Control Panels
22 AWG 2 conductor 7 strand bare copper with polyvinylchloride insulation, unshielded with an overall PVC jacket. (UL) CL3R Sun Res or CM C(UL)US 75°C, for Lutron Vareo Systems
Two element composite cable with an overall PVC jacket. (UL) CL3R or CMR c(UL)us 75’C 300V, for AMX AX-LINK Network and Automation Control Cable
24 AWG 4 conductors 7 strand tinned copper, foamed PP insulation, an aluminum/Mylar shield, a tinned copper drain wire, a tinned copper braid shield and an overall matte finish TPE jacket for remote of permanent installations of DMX512 lighting control applications. Made in USA
22 AWG 1 pairs cable constructed with stranded tinned copper, foam PP insulation, an aluminum/Mylar shield, a stranded drain wire, a tinned copper braid shield and an overall PVC jacket. (UL) CMR C(UL)US or AWM 2919 30V 80°C FT-1
22 AWG 2 pairs cable constructed with stranded tinned copper, foam PP insulation, an aluminum/Mylar shield, a stranded drain wire, a tinned copper braid shield and an overall PVC jacket. (UL) CM C(UL)US or AWM 2919 30V 80°C FT-1
Three element composite cable, elements pulled in parallel with an overall PVC jacket. (UL) CL3R or CMR c(UL)us 75°C, automation control cable for systems
Five element composite cable, 1 pair 22 AWG shielded, 2 conductors 18 AWG unshielded, 4 Category 5E components with an overall PVC jacket for data communications and security applications manufactured in the USA and listed (UL) CM, 75°C.
Two element composite cable, elements pulled in parallel with an overall PVC jacket. (UL) CL3R or CMR c(UL)us 75°C, automation control cable systems
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| AV162VANT-07/04* | - | 2 Conductors | - | - | - |
| AV182LUT-44/10** | 18 AWG, Class B 7 Strand | 2 Conductors | 0.045” | 0.262” | 40 lbs/Mft |
| AV184LUT-44/09** | 18 AWG, Class B 7 Strand | 4 Conductors | 0.045” | 0.313” | 64 lbs/Mft |
| AV222LUT-44/03 | - | 2 Conductors | 0.027" | 0.174” | 16 lbs/Mft |
| AVAXLINK-00 | - | - | - | - | - |
| AVB24DMX2C | - | - | 0.040” | 0.240” ± 0.010” | 37 Lbs/Mft |
| AVB24DMX4C | - | - | 0.040” Pressure | 0.270” ± 0.010” | 45 lbs/Mft |
| AVBDMX2C | - | - | 0.035” | 0.257” ± 0.010” | 40 lbs/Mft |
| AVBDMX4C | - | - | 0.035” | 0.270” ± 0.010” | 47 lbs/Mft |
| AVCRESCDM6B-60/2 | - | - | - | - | - |
| AVCRESCQ-60/09 | - | - | - | - | - |