14AWG 2C 7STR BC NS PVC/PVC (UL) ITC/PLTC/CL3 300V 105C

14/3C 7STR BC UNS ITC/PLTC/CL3 SR 300V 105C

16 AWG 2 conductors 7 strand bare copper wire, PVC insulation, with an overall PVC jacket. (UL) ITC or PLTC 105’C SUN RES DIR BUR FT-4 “ROHS”

16 AWG 2 pairs 7 strand bare copper wire, PVC insulation, unshielded, with an overall PVC jacket. (UL) ITC or PLTC 105’C SUN RES DIR BUR FT-4 “ROHS”

16 AWG 2 triads 7 strand bare copper wire, PVC insulation, unshielded, with an overall PVC jacket. (UL) ITC or PLTC 105’C SUN RES DIR BUR FT-4 “ROHS”

16 AWG 3 conductors 7 strand bare copper wire, PVC insulation, with an overall PVC jacket. (UL) ITC or PLTC 105’C SUN RES DIR BUR FT-4 “ROHS”

16 AWG 4 pairs 7 strand bare copper wire, PVC insulation, unshielded, with an overall PVC jacket. (UL) ITC or PLTC 105’C SUN RES DIR BUR FT-4 “ROHS”

16 AWG 4 triads 7 strand bare copper wire, PVC insulation, unshielded, with an overall PVC jacket. (UL) ITC or PLTC 105’C SUN RES DIR BUR FT-4 “ROHS”

16 AWG 8 pairs 7 strand bare copper wire, PVC insulation, unshielded, with an overall PVC jacket. (UL) ITC or PLTC 105’C SUN RES DIR BUR FT-4 “ROHS”

16 AWG 8 triads 7 strand bare copper wire, PVC insulation, unshielded, with an overall PVC jacket. (UL) ITC or PLTC 105’C SUN RES DIR BUR FT-4 “ROHS”

18 AWG 2 conductors 7 strand bare copper wire, PVC insulation, with an overall PVC jacket. (UL) ITC or PLTC 105’C SUN RES DIR BUR FT-4 “ROHS”

18 AWG 2 pairs 7 strand bare copper wire, PVC insulation, unshielded, with an overall PVC jacket. (UL) ITC or PLTC 105’C SUN RES DIR BUR FT-4 “ROHS”

ProductAWG Size & StrandingConductor CountJacket ThicknessCable ODCable Weight
T142 14 AWG 7 Strands Class B2 Conductors0.040”0.306”58 Lbs/Mft
T143 14 AWG 7 Strands Class B3 Conductors0.040”0.324”77 Lbs/Mft
T162 16 AWG 7 Strands Class B2 Conductors0.035”0.247”38 Lbs/Mft
T162PR 16 AWG 7 Strands Class B2 Pairs0.040”0.378”73 Lbs/Mft
T162TR 16 AWG 7 Strands Class B2 Triads0.050”0.496”114 Lbs/Mft
T163 16 AWG 7 Strands Class B3 Conductors0.035”0.267”51 Lbs/Mft
T164PR 16 AWG 7 Strands Class B4 Pairs0.050”0.460”132 Lbs/Mft
T164TR 16 AWG 7 Strands Class B4 Triads0.050”0.576”190 Lbs/Mft
T168PR 16 AWG 7 Strands Class B8 Pairs0.050”0.597”238 Lbs/Mft
T168TR 16 AWG 7 Strands Class B8 Triads0.060”0.773”358 Lbs/Mft
T182 18 AWG 7 Strands Class B2 Conductors0.035”0.224”29 Lbs/Mft
T182PR 18 AWG 7 Strands Class B2 Pairs0.040”0.333”54 Lbs/Mft