Copper Price 11/13/2026 6.1565

UNSHIELDED

Found 34 products.
View as Grid List Table
Sort by
Display per page

16 AWG 4 triad 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 4 pair 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 2 triad 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 2 pair 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

14 AWG 8 triad 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

14 AWG 8 pair 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

14 AWG 6 triad 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

14 AWG 6 pair 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

14 AWG 4 triad 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

14AWG 4PR 7STR BC UNS VNTC (UL) TC-ER-JP 600V 90C

14 AWG 2 triad 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

14 AWG 2 pair 7 strand bare copper with polyvinylchloride and nylon insulation, unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

ProductAWG Size & StrandingConductor CountJacket ThicknessCable ODCable Weight
V164TR 16 AWG 7 Strands Class B-0.060”0.638”215 lbs./Mft.
V164PR 16 AWG 7 Strands Class B-0.045”0.484”136 lbs./Mft.
V162TR 16 AWG 7 Strands Class B-0.045”0.377”110 lbs./Mft.
V162PR 16 AWG 7 Strands Class B-0.045”0.350”75 lbs./Mft.
V148TR 14 AWG 7 Strands Class B-0.080”0.895”556 lbs./Mft.
V148PR 14 AWG 7 Strands Class B-0.060”0.739”366 lbs./Mft.
V146TR 14 AWG 7 Strands Class B-0.060”0.784”405 lbs./Mft.
V146PR 14 AWG 7 Strands Class B-0.060”0.678”289 lbs./Mft.
V144TR 14 AWG 7 Strands Class B-0.060”0.654”284 lbs./Mft.
V144PR 14 AWG 7 Strands Class B-0.060”0.570”204 lbs./Mft.
V142TR 14 AWG 7 Strands Class B-0.060”0.564”174 lbs./Mft.
V142PR 14 AWG 7 Strands Class B-0.045”0.461”108 lbs./Mft.