14 AWG 8 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 8 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 2 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 2 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 2 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 3 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 4 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 4 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 6 pair 26 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 6 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 8 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 8 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VXC148PR | 14AWG, 7 Strands Class B | 8 Pairs | 0.080” | 0.887” | 497 Lbs/Mft |
| VXC148TR | 14 AWG, 7 Strands Class B | 8 triad | 0.080” | 1.622” | 1,657 Lbs/Mft |
| VXC162 | 16 AWG, 7 Strands Class B | 2 Conductors | 0.045” | 0.320” | 58 lbs./Mft. |
| VXC162PR | 16 AWG, 7 Strands Class B | 2 Pairs | 0.045” | 0.509” | 110 Lbs/Mft |
| VXC162TR | 16 AWG, 7 Strands Class B | 2 triad | 0.080” | 0.636” | 185 Lbs/Mft |
| VXC163 | 16 AWG, 7 Strands Class B | 3 Conductors | 0.045” | 0.340” | 77 lbs./Mft. |
| VXC164PR | 16 AWG, 7 Strands Class B | 4 Pairs | 0.060” | 0.610” | 200 Lbs/Mft |
| VXC164TR | 16 AWG, 7 Strands Class B | 4 triad | 0.080” | 0.742” | 289 Lbs/Mft |
| VXC166PR | 16 AWG, 26 Strands Class B | 6 Pairs | 0.060” | 0.745” | 286 Lbs/Mft |
| VXC166TR | 16 AWG, 7 Strands Class B | 6 triad | 0.080” | 1.236” | 803 Lbs/Mft |
| VXC168PR | 16 AWG, 7 Strands Class B | 8 Pairs | 0.060” | 0.780” | 352 Lbs/Mft |
| VXC168TR | 16 AWG, 7 Strands Class B | 8 triad | 0.080” | 1.469” | 1,246 Lbs/Mft |