12 AWG 4 conductor 65 strand bare copper with TPE insulation, unshielded with an overall TPE jacket 300V flex cord cable, approved for use in sunlight and weather resistant 105°C applications.
14 AWG 2 conductor 41 strand bare copper with TPE insulation, unshielded with an overall TPE jacket 300V flex cord cable, approved for use in sunlight and weather resistant 105°C applications.
16 AWG 2 conductor 26 strand bare copper with TPE insulation, unshielded with an overall TPE jacket 300V flex cord cable, approved for use in sunlight and weather resistant 105°C applications.
16 AWG 3 conductor 26 strand bare copper with TPE insulation, unshielded with an overall TPE jacket 300V flex cord cable, approved for use in sunlight and weather resistant 105°C applications.
16 AWG 4 conductor 26 strand bare copper with TPE insulation, unshielded with an overall TPE jacket 300V flex cord cable, approved for use in sunlight and weather resistant 105°C applications.
16 AWG 5 conductor 26 strand bare copper with TPE insulation, unshielded with an overall TPE jacket 300V flex cord cable, approved for use in sunlight and weather resistant 105°C applications.
18 AWG 2 conductor 16 strand bare copper with TPE insulation, unshielded with an overall TPE jacket 300V flex cord cable, approved for use in sunlight and weather resistant 105°C applications.
18 AWG 3 conductor 16 strand bare copper with TPE insulation, unshielded with an overall TPE jacket 300V flex cord cable, approved for use in sunlight and weather resistant 105°C applications.
18 AWG 4 conductor 16 strand bare copper with TPE insulation, unshielded with an overall TPE jacket 300V flex cord cable, approved for use in sunlight and weather resistant 105°C applications.
18 AWG 5 conductor 16 strand bare copper with TPE insulation, unshielded with an overall TPE jacket 300V flex cord cable, approved for use in sunlight and weather resistant 105°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| SJEOOW124 | 12 AWG 65 Strands Class K | 4 Conductors | 0.047” | 0.480” | 166 lbs./Mft. |
| SJEOOW142 | 14 AWG 41 Strands | 2 Conductors | 0.032” | 0.344” | 65 lbs./Mft. |
| SJEOOW162 | 16 AWG 26 Strands | 2 Conductors | 0.032” | 0.318” | 51 lbs./Mft. |
| SJEOOW163 | 16 AWG 26 Strands | 3 Conductors | 0.032” | 0.338” | 67 lbs./Mft. |
| SJEOOW164 | 16 AWG 26 Strands | 4 Conductors | 0.032” | 0.369” | 85 lbs./Mft. |
| SJEOOW165 | 16 AWG 26 Strands | 5 Conductors | 0.032” | 0.404” | 98 lbs./Mft. |
| SJEOOW182 | 18 AWG 16 Strands | 2 Conductors | 0.032” | 0.292” | 40 lbs./Mft. |
| SJEOOW183 | 18 AWG 16 Strands | 3 Conductors | 0.032” | 0.310” | 52 lbs./Mft. |
| SJEOOW184 | 18 AWG 16 Strands | 4 Conductors | 0.032” | 0.338” | 65 lbs./Mft. |