14 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
14 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
16 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
16 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
18 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
18 AWG 3 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
18 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
18 AWG 6 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| V142S/14DR-QR | 14 AWG, 7 Strands Class B | 2 Conductors | 0.045” | 0.319” | 74 lbs./Mft. |
| V144S-QR | 14 AWG, 7 Strands Class B | 4 Conductors | 0.045” | 0.365” | 104 lbs./Mft. |
| V162S/16DR-QR | 16 AWG, 7 Strands Class B | 2 Conductors | 0.045” | 0.291” | 55 lbs./Mft. |
| V164S-QR | 16 AWG, 7 Strands Class B | 4 Conductors | 0.045” | 0.331” | 78 lbs./Mft. |
| V182S/18DR-QR | 18 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.263” | 42 lbs/Mft |
| V183S-QR | 18 AWG, 7 Strands Class B | 3 Conductors | 0.045” | 0.273” | 49 lbs./Mft. |
| V184S-QR | 18 AWG, 7 Strands Class B | 4 Conductors | 0.045” | 0.283” | 58 lbs./Mft. |
| V186S-QR | 18 AWG, 7 Strands Class B | 6 Conductors | 0.045” | 0.347” | 80 lbs./Mft. |