14 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation unshielded with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
16 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation unshielded with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
18 AWG 3 conductor 7 strand bare copper with polyvinylchloride and nylon insulation unshielded with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
18 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation unshielded with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
18 AWG 6 conductor 7 strand bare copper with polyvinylchloride and nylon insulation unshielded with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications.
12 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an uninsulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications. 1. Conductor 1.1. AWG Size & Stranding: 12 AWG, 7 Strands Class B 1.2. Material: Annealed Bare Copper 1.3. Conductor Count: 2 Conductors
14 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an uninsulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications. 1. Conductor 1.1. AWG Size & Stranding: 14 AWG, 7 Strands Class B 1.2. Material: Annealed Bare Copper 1.3. Conductor Count: 2 Conductors
16 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an uninsulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications. 1. Conductor 1.1. AWG Size & Stranding: 16 AWG, 7 Strands Class B 1.2. Material: Annealed Bare Copper 1.3. Conductor Count: 2 Conductors
18 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, an uninsulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, PLTC, NPLF & FPL, approved for use in SUN RES DIR BUR OIL RES I 90°C applications. 1. Conductor 1.1. AWG Size & Stranding: 18 AWG, 7 Strands Class B 1.2. Material: Annealed Bare Copper 1.3. Conductor Count: 2 Conductors
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| V144-QR | 14 AWG, 7 Strands Class B | 4 Conductors | 0.045” | 0.350” | 98 lbs./Mft. |
| V164-QR | 16 AWG, 7 Strands Class B | 4 Conductors | 0.045” | 0.329” | 74 lbs./Mft. |
| V183-QR | 18 AWG, 7 Strands Class B | 3 Conductors | 0.045” | 0.274” | 44 lbs./Mft. |
| V184-QR | 18 AWG, 7 Strands Class B | 4 Conductors | 0.045” | 0.290” | 54 lbs./Mft. |
| V186-QR | 18 AWG, 7 Strands Class B | 6 Conductors | 0.045” | 0.340” | 76 lbs./Mft. |
| VG122-QR | - | - | 0.045” | 0.351” | 100 lbs./Mft. |
| VG142-QR | - | - | 0.045” | 0.312” | 74 lbs./Mft. |
| VG162-QR | - | - | 0.045” | 0.276” | 53 lbs./Mft. |
| VG182-QR | - | - | 0.045” | 0.270” | 42 lbs./Mft. |