12 AWG 9 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 12 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 15 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 19 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 2 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 3 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 30 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 37 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 4 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 5 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 6 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 7 conductor 7 strand bare copper with XLPE insulation, unshielded with an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VXC129 | 12 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.684” | 361 lbs./Mft. |
| VXC1412 | 14 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.650” | 338 lbs./Mft. |
| VXC1415 | 14 AWG, 7 Strands Class B | 15 Conductors | 0.060” | 0.725” | 410 lbs./Mft. |
| VXC1419 | 14 AWG 7 Strands Class B | 19 Conductors | 0.060” | 0.780” | 508 lbs./Mft. |
| VXC142 | 14 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.355” | 74 lbs./Mft. |
| VXC143 | 14 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.378” | 96 lbs./Mft. |
| VXC1430 | 14 AWG 7 Strands Class B | 30 Conductors | 0.080” | 1.017” | 854 lbs./Mft. |
| VXC1437 | 14 AWG 7 Strands Class B | 37 Conductors | 0.080” | 1.096” | 1,011 lbs./Mft. |
| VXC144 | 14 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.403” | 129 lbs./Mft. |
| VXC145 | 14 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.440” | 149 lbs./Mft. |
| VXC146 | 14 AWG, 7 Strands Class B | 6 Conductors | 0.045” | 0.489” | 173 lbs./Mft. |
| VXC147 | 14 AWG 7 Strands Class B | 7 Conductors | 0.045” | 0.492” | 195 lbs./Mft. |