6 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
8 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
8 AWG 3 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
8 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
1/0 AWG 3 conductor 19 strand bare copper with cross-linked polyethylene insulation, an XLPE insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
1/0 AWG 4 conductor 19 strand bare copper with cross-linked polyethylene insulation, an XLPE insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
10 AWG 2 conductor 7 strand bare copper with cross-linked polyethylene insulation, an XLPE insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
10 AWG 3 conductor 7 strand bare copper with cross-linked polyethylene insulation, an XLPE insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
10 AWG 4 conductor 7 strand bare copper with cross-linked polyethylene insulation, an XLPE insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
2/0 AWG 3 conductor 19 strand bare copper with cross-linked polyethylene insulation, an XLPE insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
2/0 AWG 4 conductor 19 strand bare copper with cross-linked polyethylene insulation, an XLPE insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
2 AWG 3 conductor 7 strand bare copper with cross-linked polyethylene insulation, an XLPE insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VIG64 | 6 AWG, 7 Strands Class B | 4 Conductors | 0.060” | 0.795” | 606 lbs./Mft. |
| VIG82 | 8 AWG, 7 Strands Class B | 2 Conductors | 0.060” | 0.559” | 250 lbs./Mft. |
| VIG83 | 8 AWG, 7 Strands Class B | 3 Conductors | 0.060” | 0.620” | 326 lbs./Mft. |
| VIG84 | 8 AWG, 7 Strands Class B | 4 Conductors | 0.060” | 0.686” | 428 lbs./Mft. |
| VIGX1/03 | 1/0 AWG, 19 Strands Class B | 3 Conductors | 0.080” | 1.225” | 1476 lbs./Mft. |
| VIGX1/04 | 1/0 AWG, 19 Strands Class B | 4 Conductors | 0.080” | 1.376” | 1946 lbs./Mft. |
| VIGX102 | 10 AWG, 7 Strands Class B | 2 Conductors | 0.045” | 0.471” | 175 lbs./Mft. |
| VIGX103 | 10 AWG, 7 Strands Class B | 3 Conductors | 0.060” | 0.545” | 240 lbs./Mft. |
| VIGX104 | 10 AWG, 7 Strands Class B | 4 Conductors | 0.060” | 0.596” | 295 lbs./Mft. |
| VIGX2/03 | 2/0 AWG, 19 Strands Class B | 3 Conductors | 0.080” | 1.316” | 1812 lbs./Mft. |
| VIGX2/04 | 2/0 AWG, 19 Strands Class B | 4 Conductors | 0.080” | 1.483” | 2309 lbs./Mft. |
| VIGX23 | 2 AWG, 7 Strands Class B | 3 Conductors | 0.080” | 0.989” | 1010 lbs./Mft. |