4 AWG 5C 413STR BC + INS GND PVC/PVC (UL) TC-ER 90C 600V OR STOOW 600V
SKU: SSTOOWIG45-OM
 

4 AWG 5 CONDUCTOR 413 STRAND BARE COPPER WITH PVC INSULATION, AN INSULATED BARE COPPER GROUND, UNSHIELDED, WITH AN OVERALL PVC JACKET 600V FLEX CORD CABLE, APPROVED FOR USE IN SUNLIGHT AND WEATHER RESISTANT 105C APPLICATIONS AS WELL AS CONTROL TRAY CABLE 90˚C APPLICATIONS.

This spec is for informational purposes and subject to change. This spec may not be suitable for submission. Contact Lake Cable for non-watermark spec sheet.

Products specifications

Conductor

AWG Size & Stranding:
4 AWG 413 Strands Class K
Material:
Annealed Bare Copper
Conductor Count:
5 Conductors

Insulation

Material:
Polyvinylchloride
Wall Thickness:
0.062”
Color Code:
Method 1, Table E-2

Assembly

Ground:
Insulated Green, 8 AWG 168 strands bare copper
Fillers:
Non-Hygroscopic Polypropylene - As required for a circular cross-section
Binder:
Non-Woven Wrap

Jacket

Material:
Polyvinylchloride
Wall Thickness:
0.158”
1.387” +/- 0.070”
Color:
Black
Ripcord:
Yes (2-Ply)
Cold Bend Rating:
-40°C
Weight:
1472 lbs./Mft.

Markings

Type:
Cable shall be permanently identified via surface inkjet print
Legend:
LAKE CABLE E208309 4AWG (21.2MM2) 5C (UL) TC-ER THW-2/VW-1 INSULATED GROUND 600V 90C DRY/WET PVC JACKET SUN RES DIR BUR OIL RES I & II FT4 OR C(UL)US STOOW VW-1 105C 600V FT2 WATER RESISTANT SUN RES “ROHS COMPLIANT” MADE IN USA
Footage Markers:
Yes. Ascending

Approvals

Approvals List:

• Refer to NEC (NFPA 70) article 336 for installation guidelines
• Cable is suitable for use in Class I Division 2 hazardous locations
• UL listed as Type TC-ER per UL Standard 1277 for tray cables
• UL approved for Direct Burial, Sunlight and Oil I & II Resistant applications per UL 1277
• Individual conductors pass UL VW-1 flame test, rated THW-2/VW-1
• UL listed as Type STOOW per UL Standard 62 for flexible cords
• UL approved for Sunlight, Oil and Weather Resistant & Water Submersed applications per UL 62
• Cable meets UL 1581 & 1202 (FT-4) 70,000 BTU/HR
• Cable meets RoHS 2002/95/EC Directive, RoHS 2 2011/65/EU Directive, RoHS 3 2015/863/EU Directive
• Cable is REACH compliant per Regulation (EC) No 1907/2006 (240) Updated January 23, 2024
• Made in the USA
• For tray cable: 76 amps, Ampacity based on values published in NEC Table 310.16. Value based on wire insulations rated 90°C in ambient temperature of 30°C and Adjustment Factors for more than 3 current-carrying conductors per table 310.15(b)(16)
• For portable cords: 48 amps, Ampacity based on values published in NEC Table 400.5(A)(1). Values based on wire insulations rated for 90C in ambient temperature of 30C and Adjustment factors for more than 3 current-carrying conductors per table 400.5(A)(3).
• WARNING: This product may contain chemicals, such as Vinyl Chloride, known to the state of California to cause cancer. For more information, go to www.P65Warnings.ca.gov. Wash hands after handling.

Remember, all of our wire can feature:

  • Short minumum runs
  • Special jacket colors including stripes
  • Custom print legends
  • Custom cable constructions
  • Custom packaging - boxes or reels
  • Custom lengths
  • Your name on package labels