18 AWG 5PR 7STR BC SPOS XLPE/LSZH (UL) TC-ER-ST1 600V 90C
SKU: VXH185SPOS
 

18 AWG 5 PAIR 7 STRAND BARE COPPER WIRE WITH .030" LS-XLPE INSULATION, EACH PAIR IS INDIVIDUALLY SHIELDED WITH FOIL-FREE EDGED ALUMINUM MYLAR TAPE SHIELDS WITH 20 AWG 7 STRAND TINNED COPPER DRAIN WIRES, OVERALL ALUMINUM MYLAR TAPE SHIELD WITH AN 18 AWG 7 STRAND TINNED COPPER DRAIN WIRE, OVERALL .060" BLACK LOW SMOKE ZERO HALOGEN JACKET. (UL) TC-ER 600V "LS" XLPE 90'C DRY/WET SUN RES DIR BUR "ROHS" IEEE 1202 FT-4
CC: BLACK & WHITE NUMBERED PAIRS

This spec is for informational purposes and subject to change. This spec may not be suitable for submission. Contact Lake Cable for non-watermark spec sheet.

Products specifications

Conductor

AWG Size & Stranding:
18 AWG 7 Strands Class B
Material:
Annealed Bare Copper
Pair Count:
5 Pair

Insulation

Material:
Cross-linked Polyethylene
Wall Thickness:
0.030”
Color Code:
Black & White numbered pairs

Assembly

Pair/ Cable Lay Length:
Per UL Standard 1277
Pair Drain Wire:
20 AWG 7 Strand Tinned Copper
Pair Shield:
Foil Free Edged Aluminum/Mylar Tape – 100% coverage
Cable Binder:
Clear Mylar – if required
Cable Shield:
Aluminum/Mylar Tape – 100% coverage
Cable Drain Wire:
18 AWG 7 Strand Tinned Copper

Jacket

Material:
Low Smoke FR Zero Halogen Polyolefin (LSFR-0HPO)
Wall Thickness:
0.060"
Diameter:
0.617"
Color:
Black
Ripcord:
Yes
Weight:
199 lbs./Mft.

Markings

Type:
Cable shall be permanently identified via surface inkjet print
Legend:
LAKE CABLE E208309 18AWG 5PR SPOS (UL) TC-ER-ST-1 XLPE 600V 90’C DRY/WET LSZH JACKET SUN RES DIR BUR “ROHS COMPLIANT” IEEE 1202 FT4 MADE IN USA
Footage Markers:
Yes

Approvals

Approvals List:

• Refer to NEC (NFPA 70) article 336 for installation guidelines
• Cable is suitable for use in Class I Division II hazardous locations
• UL listed as Type TC per UL Standard 1277 for tray cables with 2 conductors
• UL listed as Type TC-ER per UL Standard 1277 for tray cables 3+ conductors
• UL approved for Direct Burial, Sunlight Resistant & Low Smoke applications
• Cable meets IEEE 383 & UL 1581 70,000 BTU/HR flame test requirements
• Meets ICEA S-73-532, where applicable
• Cable is RoHS III compliant per Directive 2015/863/EU
• Cable is REACH compliant per Regulation (EC) No 1907/2006 Updated July, 7 2017
• Made in the USA