Copper Price 10/2/2026 6.5185

UNSHIELDED

Found 34 products.
View as Grid List Table
Sort by
Display per page

18 AWG 8 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

18 AWG 6 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

18 AWG 6 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

18 AWG 4 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

18 AWG 4 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

18 AWG 2 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

18 AWG 2 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

16 AWG 8 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

16 AWG 8 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

16 AWG 6 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

16 AWG 6 pair 26 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

16 AWG 4 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

ProductAWG Size & StrandingConductor CountJacket ThicknessCable ODCable Weight
VXC188PR 18 AWG, 7 Strands Class B8 Pairs0.060”0.690”262 Lbs/Mft
VXC186TR 18 AWG, 7 Strands Class B6 triad0.080”1.080”628 Lbs/Mft
VXC186PR 18 AWG, 7 Strands Class B6 Pairs0.060”0.636”214 Lbs/Mft
VXC184TR 18 AWG, 7 Strands Class B4 triad0.060”0.670”220 Lbs/Mft
VXC184PR 18 AWG, 7 Strands Class B4 Pairs0.060”0.535”149 Lbs/Mft
VXC182TR 18 AWG, 7 Strands Class B2 triad0.060”0.576”135 Lbs/Mft
VXC182PR 18 AWG, 7 Strands Class B2 Pairs0.045”0.458”89 Lbs/Mft
VXC168TR 16 AWG, 7 Strands Class B8 triad0.080”1.469”1,246 Lbs/Mft
VXC168PR 16 AWG, 7 Strands Class B8 Pairs0.060”0.780”352 Lbs/Mft
VXC166TR 16 AWG, 7 Strands Class B6 triad0.080”1.236”803 Lbs/Mft
VXC166PR 16 AWG, 26 Strands Class B6 Pairs0.060”0.745”286 Lbs/Mft
VXC164TR 16 AWG, 7 Strands Class B4 triad0.080”0.742”289 Lbs/Mft