UNSHIELDED

Found 33 products.
View as Grid List Table
Sort by
Display per page

10 AWG 2 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

10 AWG 2 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

12 AWG 2 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

12 AWG 2 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

12 AWG 4 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

12 AWG 4 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

14 AWG 2 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

14 AWG 2 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

14 AWG 4 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

14 AWG 4 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

14 AWG 6 pair 7 strand bare copper with XLPE insulation, unshielded with kevlar strength members, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

14 AWG 6 triad 7 strand bare copper with XLPE insulation, unshielded, a mylar wrap binder and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.

ProductAWG Size & StrandingConductor CountJacket ThicknessCable ODCable Weight
VXC102PR 10 AWG, 7 Strands Class B2 Pairs0.060”0.700”275 Lbs/Mft
VXC102TR 10 AWG, 7 Strands Class B2 triad0.060”0.737”291 Lbs/Mft
VXC122PR 12 AWG, 7 Strands Class B2 Pairs0.060”0.665”214 Lbs/Mft
VXC122TR 12 AWG, 7 Strands Class B2 triad0.060”0.631”204 Lbs/Mft
VXC124PR 12 AWG, 7 Strands Class B4 Pairs0.060”1.020”676 Lbs/Mft
VXC124TR 12 AWG, 7 Strands Class B4 triad0.080”1.062”717 Lbs/Mft
VXC142PR 14AWG, 7 Strands Class B2 Pairs0.060”0.556”151 Lbs/Mft
VXC142TR 14 AWG, 7 Strands Class B2 triad0.060”0.590”164 Lbs/Mft
VXC144PR 14AWG, 7 Strands Class B4 Pairs0.060”0.648”258 Lbs/Mft
VXC144TR 14 AWG, 7 Strands Class B4 triad0.080”0.937”504 Lbs/Mft
VXC146PR 14AWG, 7 Strands Class B6 Pairs0.060”0.777”367 Lbs/Mft
VXC146TR 14 AWG, 7 Strands Class B6 triad0.080”1.362”1,036 Lbs/Mft