10 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
8 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
8 AWG 3 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
8 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
6 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
6 AWG 3 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
6 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
4 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
4 AWG 2 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
2 AWG 4 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
2 AWG 3 conductor 7 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
4/0 AWG 4 conductor 19 strand bare copper with polyvinylchloride and nylon insulation, a polyvinylchloride and nylon insulated bare copper ground conductor unshielded with an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VIG102 | 10 AWG, 7 Strands Class B | 2 Conductors | 0.045” | 0.445” | 159 lbs./Mft. |
| VIG84 | 8 AWG, 7 Strands Class B | 4 Conductors | 0.060” | 0.686” | 428 lbs./Mft. |
| VIG83 | 8 AWG, 7 Strands Class B | 3 Conductors | 0.060” | 0.620” | 326 lbs./Mft. |
| VIG82 | 8 AWG, 7 Strands Class B | 2 Conductors | 0.060” | 0.559” | 250 lbs./Mft. |
| VIG64 | 6 AWG, 7 Strands Class B | 4 Conductors | 0.060” | 0.795” | 606 lbs./Mft. |
| VIG63 | 6 AWG, 7 Strands Class B | 3 Conductors | 0.060” | 0.718” | 467 lbs./Mft. |
| VIG62 | 6 AWG, 7 Strands Class B | 2 Conductors | 0.060” | 0.656” | 355 lbs./Mft. |
| VIG44 | 4 AWG, 7 Strands Class B | 4 Conductors | 0.080” | 0.996” | 904 lbs./Mft. |
| VIG42 | 4 AWG, 7 Strands Class B | 2 Conductors | 0.060” | 0.759” | 496 lbs./Mft. |
| VIG24 | 2 AWG, 7 Strands Class B | 4 Conductors | 0.080” | 1.148” | 1314 lbs./Mft. |
| VIG23 | 2 AWG, 7 Strands Class B | 3 Conductors | 0.080” | 1.028” | 1048 lbs./Mft. |
| VIG4/04 | 4/0 AWG, 19 Strands Class B | 4 Conductors | 0.110” | 1.830” | 3566 lbs./Mft. |