18 AWG 5 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
18 AWG 4 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
18 AWG 3 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
18 AWG 2 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
16 AWG 9 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
16 AWG 7 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
16 AWG 6 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
16 AWG 5 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
16 AWG 4 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
16 AWG 3 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
16 AWG 2 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
14 AWG 9 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| TPT185S | 18 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.350” | 74 lbs./Mft. |
| TPT184S | 18 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.322” | 64 lbs./Mft. |
| TPT183S | 18 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.398” | 53 lbs./Mft. |
| TPT182S | 18 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.283” | 43 lbs./Mft. |
| TPT169S | 16 AWG 7 Strands Class B | 9 Conductors | 0.045” | 0.489” | 155 lbs./Mft. |
| TPT167S | 16 AWG 7 Strands Class B | 7 Conductors | 0.045” | 0.420” | 125 lbs./Mft. |
| TPT166S | 16 AWG 7 Strands Class B | 6 Conductors | 0.045” | 0.420” | 112 lbs./Mft. |
| TPT165S | 16 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.387” | 97 lbs./Mft. |
| TPT164S | 16 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.356” | 81 lbs./Mft. |
| TPT163S | 16 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.328” | 67 lbs./Mft. |
| TPT162S | 16 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.311” | 55 lbs./Mft. |
| TPT149S | 14 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.608” | 245 lbs./Mft. |