14 AWG 7 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
14 AWG 6 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
14 AWG 5 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
14 AWG 4 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
14 AWG 3 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
14 AWG 2 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
12 AWG 9 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
12 AWG 7 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
12 AWG 6 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
12 AWG 5 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
12 AWG 4 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
12 AWG 3 conductor 7 strand bare copper with PE and PVC insulation, an aluminum/mylar shield with a stranded tinned copper drain wire with an overall PVC jacket 600V cable, approved for use in circuits rated 600V, 75°C.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| TPT147S | 14 AWG 7 Strands Class B | 7 Conductors | 0.045” | 0.496” | 182 lbs./Mft. |
| TPT146S | 14 AWG 7 Strands Class B | 6 Conductors | 0.045” | 0.496” | 164 lbs./Mft. |
| TPT145S | 14 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.456” | 141 lbs./Mft. |
| TPT144S | 14 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.417” | 119 lbs./Mft. |
| TPT143S | 14 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.384” | 96 lbs./Mft. |
| TPT142S | 14 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.363” | 75 lbs./Mft. |
| TPT129S | 12 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.688” | 337 lbs./Mft. |
| TPT127S | 12 AWG 7 Strands Class B | 7 Conductors | 0.060” | 0.595” | 269 lbs./Mft. |
| TPT126S | 12 AWG 7 Strands Class B | 6 Conductors | 0.060” | 0.595” | 252 lbs./Mft. |
| TPT125S | 12 AWG 7 Strands Class B | 5 Conductors | 0.060” | 0.546” | 215 lbs./Mft. |
| TPT124S | 12 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.471” | 167 lbs./Mft. |
| TPT123S | 12 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.431” | 136 lbs./Mft. |