12 AWG 20 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 20 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 21 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 21 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 25 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 25 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 3 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 3 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 4 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 4 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 5 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 5 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| IM1911220/1 | 12 AWG Solid | 20 Conductors | 0.080” | 0.895” | 650 lbs./Mft. |
| IM1911220/7 | 12 AWG 7 Strands Class B | 20 Conductors | 0.080” | 0.968” | 677 lbs./Mft. |
| IM1911221/1 | 12 AWG Solid | 21 Conductors | 0.080” | 0.913” | 660 lbs./Mft. |
| IM1911221/7 | 12 AWG 7 Strands Class B | 21 Conductors | 0.080” | 0.988” | 707 lbs./Mft. |
| IM1911225/1 | 12 AWG Solid | 25 Conductors | 0.080” | 0.999” | 797 lbs./Mft. |
| IM1911225/7 | 12 AWG 7 Strands Class B | 25 Conductors | 0.080” | 1.083” | 781 lbs./Mft. |
| IM191123/1 | 12 AWG Solid | 3 Conductors | 0.045” | 0.396” | 109 lbs./Mft. |
| IM191123/7 | 12 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.427” | 114 lbs./Mft. |
| IM191124/1 | 12 AWG Solid | 4 Conductors | 0.045” | 0.432” | 139 lbs./Mft. |
| IM191124/7 | 12 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.466” | 146 lbs./Mft. |
| IM191125/1 | 12 AWG Solid | 5 Conductors | 0.0473” | 0.473” | 170 lbs./Mft. |
| IM191125/7 | 12 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.511” | 175 lbs./Mft. |