14 AWG 12 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 12 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 10 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 10 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 25 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 25 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 21 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 21 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 20 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 20 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 19 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
18 AWG 2 pairs solid bare copper with PE insulation, a PE inner belt, 0.005” thick annealed helical bare copper tape with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, or for direct earth burial either as fire protective signaling cable or as traffic signal cable.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| IM1911412/7 | 14 AWG 7 strands Class B | 12 Conductors | 0.060” | 0.635” | 276 lbs./Mft. |
| IM1911412/1 | 14 AWG Solid | 12 Conductors | 0.060” | 0.597” | 263 lbs./Mft. |
| IM1911410/7 | 14 AWG 7 strands Class B | 10 Conductors | 0.060” | 0.615” | 240 lbs./Mft. |
| IM1911410/1 | 14 AWG Solid | 10 Conductors | 0.060” | 0.579” | 228 lbs./Mft. |
| IM1911225/7 | 12 AWG 7 Strands Class B | 25 Conductors | 0.080” | 1.083” | 781 lbs./Mft. |
| IM1911225/1 | 12 AWG Solid | 25 Conductors | 0.080” | 0.999” | 797 lbs./Mft. |
| IM1911221/7 | 12 AWG 7 Strands Class B | 21 Conductors | 0.080” | 0.988” | 707 lbs./Mft. |
| IM1911221/1 | 12 AWG Solid | 21 Conductors | 0.080” | 0.913” | 660 lbs./Mft. |
| IM1911220/7 | 12 AWG 7 Strands Class B | 20 Conductors | 0.080” | 0.968” | 677 lbs./Mft. |
| IM1911220/1 | 12 AWG Solid | 20 Conductors | 0.080” | 0.895” | 650 lbs./Mft. |
| IM1911219/7 | 12 AWG 7 Strands Class B | 19 Conductors | 0.080” | 0.940” | 647 lbs./Mft. |
| IM196182PRSCU/1 | 18 AWG Solid | 2 Pairs | - | - | - |