14 AWG 2 pairs solid bare copper with PE insulation, a PE inner belt, 0.005” thick annealed helical bare copper tape with an overall PVC jacket 600V, suitable for severe service in underground conduit or as aerial cable supported by a messenger, or for direct earth burial either as fire protective signaling cable or as traffic signal cable.
12 AWG 19 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 16 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 16 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 15 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 15 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 12 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 12 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 10 conductor stranded bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 10 conductor solid bare copper with PE insulation, unshielded with an overall PVC jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 9 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| IM196162PRSCU/1 | 16 AWG Solid | 2 Pairs | - | - | - |
| IM196142PRSCU/1 | 14 AWG Solid | 2 Pairs | - | - | - |
| IM1911219/1 | 12 AWG Solid | 19 Conductors | 0.080” | 0.869” | 621 lbs./Mft. |
| IM1911216/7 | 12 AWG 7 Strands Class B | 16 Conductors | 0.080” | 0.892” | 558 lbs./Mft. |
| IM1911216/1 | 12 AWG Solid | 16 Conductors | 0.060” | 0.784” | 490 lbs./Mft. |
| IM1911215/7 | 12 AWG 7 Strands Class B | 15 Conductors | 0.080” | 0.870” | 501 lbs./Mft. |
| IM1911215/1 | 12 AWG Solid | 15 Conductors | 0.060” | 0.766” | 475 lbs./Mft. |
| IM1911212/7 | 12 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.767” | 405 lbs./Mft. |
| IM1911212/1 | 12 AWG Solid | 12 Conductors | 0.060” | 0.708” | 390 lbs./Mft. |
| IM1911210/7 | 12 AWG 7 Strands Class B | 10 Conductors | 0.060” | 0.743” | 344 lbs./Mft. |
| IM1911210/1 | 12 AWG Solid | 10 Conductors | 0.060” | 0.686” | 335 lbs./Mft. |
| IM191149/7 | 14 AWG 7 strands Class B | 9 Conductors | 0.060” | 0.568” | 218 lbs./Mft. |