Copper Price 12/5/2025 5.3545

SHIELDED

Found 60 products.
View as Grid List Table
Sort by
Display per page

12 AWG 30 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

12 AWG 37 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

12 AWG 3 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

12 AWG 4 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

12 AWG 5 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

12 AWG 6 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

12 AWG 7 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

12 AWG 8 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

12 AWG 9 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

14 AWG 12 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

14 AWG 15 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

14 AWG 19 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

ProductAWG Size & StrandingConductor CountJacket ThicknessCable ODCable Weight
VX1230S 12 AWG 7 Strands Class B30 Conductors0.080”1.165”1076 lbs./Mft.
VX1237S 12 AWG 7 Strands Class B37 Conductors0.080”1.256”1296 lbs./Mft.
VX123S 12 AWG 7 Strands Class B3 Conductors0.045”0.430”139 lbs./Mft.
VX124S 12 AWG 7 Strands Class B4 Conductors0.045”0.467”164 lbs./Mft.
VX125S 12 AWG 7 Strands Class B5 Conductors0.060”0.544”220 lbs./Mft.
VX126S 12 AWG 7 Strands Class B6 Conductors0.060”0.591”253 lbs./Mft.
VX127S 12 AWG 7 Strands Class B7 Conductors0.060”0.591”282 lbs./Mft.
VX128S 12 AWG 7 Strands Class B8 Conductors0.060”0.639”317 lbs./Mft.
VX129S 12 AWG 7 Strands Class B9 Conductors0.060”0.687”352 lbs./Mft.
VX1412S 14 AWG 7 Strands Class B12 Conductors0.060”0.682”332 lbs./Mft.
VX1415S 14 AWG 7 Strands Class B15 Conductors0.060”0.734”400 lbs./Mft.
VX1419S 14 AWG 7 Strands Class B19 Conductors0.060”0.793”489 lbs./Mft.