
14 AWG 2 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 30 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 37 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 3 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 4 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 5 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 6 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 7 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 8 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 9 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 12 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 15 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VX142S | 14 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.359” | 79 lbs./Mft. |
| VX1430S | 14 AWG 7 Strands Class B | 30 Conductors | 0.080” | 1.024” | 781 lbs./Mft. |
| VX1437S | 14 AWG 7 Strands Class B | 37 Conductors | 0.080” | 1.102” | 938 lbs./Mft. |
| VX143S | 14 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.418” | 111 lbs./Mft. |
| VX144S | 14 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.413” | 122 lbs./Mft. |
| VX145S | 14 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.452” | 145 lbs./Mft. |
| VX146S | 14 AWG 7 Strands Class B | 6 Conductors | 0.045” | 0.492” | 169 lbs./Mft. |
| VX147S | 14 AWG 7 Strands Class B | 7 Conductors | 0.045” | 0.492” | 189 lbs./Mft. |
| VX148S | 14 AWG 7 Strands Class B | 8 Conductors | 0.060” | 0.564” | 231 lbs./Mft. |
| VX149S | 14 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.626” | 262 lbs./Mft. |
| VX1612S | 16 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.616” | 249 lbs./Mft. |
| VX1615S | 16 AWG 7 Strands Class B | 15 Conductors | 0.060” | 0.667” | 298 lbs./Mft. |