16 AWG 19 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 2 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 30 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 37 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 3 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 4 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 5 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 6 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 7 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 8 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 9 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
18 AWG 12 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VX1619S | 16 AWG 7 Strands Class B | 19 Conductors | 0.060” | 0.723” | 365 lbs./Mft. |
| VX162S | 16 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.331” | 59 lbs./Mft. |
| VX1630S | 16 AWG 7 Strands Class B | 30 Conductors | 0.080” | 0.934” | 585 lbs./Mft. |
| VX1637S | 16 AWG 7 Strands Class B | 37 Conductors | 0.080” | 1.004” | 698 lbs./Mft. |
| VX163S | 16 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.350” | 77 lbs./Mft. |
| VX164S | 16 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.363” | 91 lbs./Mft. |
| VX165S | 16 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.414” | 111 lbs./Mft. |
| VX166S | 16 AWG 7 Strands Class B | 6 Conductors | 0.045” | 0.450” | 128 lbs./Mft. |
| VX167S | 16 AWG 7 Strands Class B | 7 Conductors | 0.045” | 0.450” | 142 lbs./Mft. |
| VX168S | 16 AWG 7 Strands Class B | 8 Conductors | 0.045” | 0.487” | 160 lbs./Mft. |
| VX169S | 16 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.555” | 195 lbs./Mft. |
| VX1812S | 18 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.563” | 193 lbs./Mft. |