16 AWG 19 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 2 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 30 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 37 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 3 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 4 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 5 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 6 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 7 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 8 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

16 AWG 9 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

18 AWG 12 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.

ProductAWG Size & StrandingConductor CountJacket ThicknessCable ODCable Weight
VX1619S 16 AWG 7 Strands Class B19 Conductors0.060”0.723”365 lbs./Mft.
VX162S 16 AWG 7 Strands Class B2 Conductors0.045”0.331”59 lbs./Mft.
VX1630S 16 AWG 7 Strands Class B30 Conductors0.080”0.934”585 lbs./Mft.
VX1637S 16 AWG 7 Strands Class B37 Conductors0.080”1.004”698 lbs./Mft.
VX163S 16 AWG 7 Strands Class B3 Conductors0.045”0.350”77 lbs./Mft.
VX164S 16 AWG 7 Strands Class B4 Conductors0.045”0.363”91 lbs./Mft.
VX165S 16 AWG 7 Strands Class B5 Conductors0.045”0.414”111 lbs./Mft.
VX166S 16 AWG 7 Strands Class B6 Conductors0.045”0.450”128 lbs./Mft.
VX167S 16 AWG 7 Strands Class B7 Conductors0.045”0.450”142 lbs./Mft.
VX168S 16 AWG 7 Strands Class B8 Conductors0.045”0.487”160 lbs./Mft.
VX169S 16 AWG 7 Strands Class B9 Conductors0.060”0.555”195 lbs./Mft.
VX1812S 18 AWG 7 Strands Class B12 Conductors0.060”0.563”193 lbs./Mft.