12 AWG 20 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 20 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 21 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 21 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 25 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 25 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 3 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 3 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 4 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 4 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 5 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 5 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| IM2011220/1 | 12 AWG Solid | 20 Conductors | 0.080” | 0.895” | 612 lbs./Mft. |
| IM2011220/7 | 12 AWG 7 Strands Class B | 20 Conductors | 0.080” | 0.968” | 635 lbs./Mft. |
| IM2011221/1 | 12 AWG Solid | 21 Conductors | 0.080” | 0.913” | 640 lbs./Mft. |
| IM2011221/7 | 12 AWG 7 Strands Class B | 21 Conductors | 0.080” | 0.988” | 665 lbs./Mft. |
| IM2011225/1 | 12 AWG Solid | 25 Conductors | 0.080” | 0.999” | 765 lbs./Mft. |
| IM2011225/7 | 12 AWG 7 Strands Class B | 25 Conductors | 0.080” | 1.083” | 781 lbs./Mft. |
| IM201123/1 | 12 AWG Solid | 3 Conductors | 0.045” | 0.396” | 103 lbs./Mft. |
| IM201123/7 | 12 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.427” | 105 lbs./Mft. |
| IM201124/1 | 12 AWG Solid | 4 Conductors | 0.045” | 0.432” | 132 lbs./Mft. |
| IM201124/7 | 12 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.466” | 141 lbs./Mft. |
| IM201125/1 | 12 AWG Solid | 5 Conductors | 0.0473” | 0.473” | 165 lbs./Mft. |
| IM201125/7 | 12 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.511” | 163 lbs./Mft. |