
12 AWG 6 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 6 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 7 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 7 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 9 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 9 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 10 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 10 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 12 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 12 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 15 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 15 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| IM201126/1 | 12 AWG Solid | 6 Conductors | 0.060” | 0.545” | 200 lbs./Mft. |
| IM201126/7 | 12 AWG 7 Strands Class B | 6 Conductors | 0.060” | 0.588” | 205 lbs./Mft. |
| IM201127/1 | 12 AWG Solid | 7 Conductors | 0.060” | 0.545” | 228 lbs./Mft. |
| IM201127/7 | 12 AWG 7 Strands Class B | 7 Conductors | 0.060” | 0.588” | 231 lbs./Mft. |
| IM201129/1 | 12 AWG Solid | 9 Conductors | 0.060” | 0.632” | 293 lbs./Mft. |
| IM201129/7 | 12 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.673” | 293 lbs./Mft. |
| IM2011410/1 | 14 AWG Solid | 10 Conductors | 0.060” | 0.579” | 210 lbs./Mft. |
| IM2011410/7 | 14 AWG 7 strands Class B | 10 Conductors | 0.060” | 0.615” | 224 lbs./Mft. |
| IM2011412/1 | 14 AWG Solid | 12 Conductors | 0.060” | 0.597” | 245 lbs./Mft. |
| IM2011412/7 | 14 AWG 7 strands Class B | 12 Conductors | 0.060” | 0.635” | 260 lbs./Mft. |
| IM2011415/1 | 14 AWG Solid | 15 Conductors | 0.060” | 0.641” | 300 lbs./Mft. |
| IM2011415/7 | 14 AWG 7 strands Class B | 15 Conductors | 0.060” | 0.728” | 329 lbs./Mft. |