14 AWG 2 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 9 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 9 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 7 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 7 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 6 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 6 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 5 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 5 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 4 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 4 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
12 AWG 3 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| IM201142/1 | 14 AWG Solid | 2 Conductors | 0.045” | 0.320” | 56 lbs./Mft. |
| IM201129/7 | 12 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.673” | 293 lbs./Mft. |
| IM201129/1 | 12 AWG Solid | 9 Conductors | 0.060” | 0.632” | 293 lbs./Mft. |
| IM201127/7 | 12 AWG 7 Strands Class B | 7 Conductors | 0.060” | 0.588” | 231 lbs./Mft. |
| IM201127/1 | 12 AWG Solid | 7 Conductors | 0.060” | 0.545” | 228 lbs./Mft. |
| IM201126/7 | 12 AWG 7 Strands Class B | 6 Conductors | 0.060” | 0.588” | 205 lbs./Mft. |
| IM201126/1 | 12 AWG Solid | 6 Conductors | 0.060” | 0.545” | 200 lbs./Mft. |
| IM201125/7 | 12 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.511” | 163 lbs./Mft. |
| IM201125/1 | 12 AWG Solid | 5 Conductors | 0.0473” | 0.473” | 165 lbs./Mft. |
| IM201124/7 | 12 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.466” | 141 lbs./Mft. |
| IM201124/1 | 12 AWG Solid | 4 Conductors | 0.045” | 0.432” | 132 lbs./Mft. |
| IM201123/7 | 12 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.427” | 105 lbs./Mft. |