18 AWG 37 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
18 AWG 30 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
18 AWG 19 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
18 AWG 15 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
18 AWG 12 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 37 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 30 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 19 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 15 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
16 AWG 12 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 37 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
14 AWG 30 conductor 7 strand bare copper with XLPE insulation, an aluminum/mylar shield with a stranded tinned copper drain wire and an overall PVC jacket 600V control tray cable, approved for use in SUN RES DIR BUR 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VX1837S | 18 AWG 7 Strands Class B | 37 Conductors | 0.080” | 0.906” | 528 lbs./Mft. |
| VX1830S | 18 AWG 7 Strands Class B | 30 Conductors | 0.060” | 0.804” | 411 lbs./Mft. |
| VX1819S | 18 AWG 7 Strands Class B | 19 Conductors | 0.060” | 0.653” | 277 lbs./Mft. |
| VX1815S | 18 AWG 7 Strands Class B | 15 Conductors | 0.060” | 0.603” | 228 lbs./Mft. |
| VX1812S | 18 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.563” | 193 lbs./Mft. |
| VX1637S | 16 AWG 7 Strands Class B | 37 Conductors | 0.080” | 1.004” | 698 lbs./Mft. |
| VX1630S | 16 AWG 7 Strands Class B | 30 Conductors | 0.080” | 0.934” | 585 lbs./Mft. |
| VX1619S | 16 AWG 7 Strands Class B | 19 Conductors | 0.060” | 0.723” | 365 lbs./Mft. |
| VX1615S | 16 AWG 7 Strands Class B | 15 Conductors | 0.060” | 0.667” | 298 lbs./Mft. |
| VX1612S | 16 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.616” | 249 lbs./Mft. |
| VX1437S | 14 AWG 7 Strands Class B | 37 Conductors | 0.080” | 1.102” | 938 lbs./Mft. |
| VX1430S | 14 AWG 7 Strands Class B | 30 Conductors | 0.080” | 1.024” | 781 lbs./Mft. |