18 AWG 2 pairs solid bare copper with PE insulation, a PE inner belt, 0.005” thick annealed helical bare copper tape with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, or for direct earth burial either as fire protective signaling cable or as traffic signal cable.
16 AWG 2 pairs solid bare copper with PE insulation, a PE inner belt, 0.005” thick annealed helical bare copper tape with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, or for direct earth burial either as fire protective signaling cable or as traffic signal cable.
14 AWG 2 pairs solid bare copper with PE insulation, a PE inner belt, 0.005” thick annealed helical bare copper tape with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, or for direct earth burial either as fire protective signaling cable or as traffic signal cable.
14 AWG 25 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 25 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 21 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 21 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 20 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 20 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 19 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 19 conductor solid bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
14 AWG 16 conductor stranded bare copper with PE insulation, unshielded with an overall PE jacket 600V, suitable for use in underground conduit or as aerial cable supported by a messenger, for installation in building raceways (not including trays), either as fire protective signaling cable or as traffic signal cable suitable for use in either wet or dry locations.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| IM206182PRSCU/1 | 18 AWG Solid | 2 Pairs | - | - | - |
| IM206162PRSCU/1 | 16 AWG Solid | 2 Pairs | - | - | - |
| IM206142PRSCU/1 | 14 AWG Solid | 2 Pairs | - | - | - |
| IM2011425/7 | 14 AWG 7 strands Class B | 25 Conductors | 0.080” | 0.855” | 544 lbs./Mft. |
| IM2011425/1 | 14 AWG Solid | 25 Conductors | 0.060” | 0.806” | 477 lbs./Mft. |
| IM2011421/7 | 14 AWG 7 strands Class B | 21 Conductors | 0.060” | 0.778” | 448 lbs./Mft. |
| IM2011421/1 | 14 AWG Solid | 21 Conductors | 0.060” | 0.728” | 401 lbs./Mft. |
| IM2011420/7 | 14 AWG 7 strands Class B | 20 Conductors | 0.060” | 0.762” | 430 lbs./Mft. |
| IM2011420/1 | 14 AWG Solid | 20 Conductors | 0.060” | 0.714” | 386 lbs./Mft. |
| IM2011419/7 | 14 AWG 7 strands Class B | 19 Conductors | 0.060” | 0.740” | 411 lbs./Mft. |
| IM2011419/1 | 14 AWG Solid | 19 Conductors | 0.060” | 0.692” | 383 lbs./Mft. |
| IM2011416/7 | 14 AWG 7 strands Class B | 16 Conductors | 0.060” | 0.701” | 334 lbs./Mft. |