18 AWG 3 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
18 AWG 2 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 9 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 8 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 7 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 6 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 5 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 4 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 3 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 2 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 9 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 8 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VXC183SCU | 18 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.336” | 88 lbs./Mft. |
| VXC182SCU | 18 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.320” | 75 lbs./Mft. |
| VXC169SCU | 16 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.567” | 236 lbs./Mft. |
| VXC168SCU | 16 AWG 7 Strands Class B | 8 Conductors | 0.045” | 0.500” | 196 lbs./Mft. |
| VXC167SCU | 16 AWG 7 Strands Class B | 7 Conductors | 0.045” | 0.463” | 178 lbs./Mft. |
| VXC166SCU | 16 AWG 7 Strands Class B | 6 Conductors | 0.045” | 0.463” | 163 lbs./Mft. |
| VXC165SCU | 16 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.425” | 142 lbs./Mft. |
| VXC164SCU | 16 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.395” | 123 lbs./Mft. |
| VXC163SCU | 16 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.366” | 105 lbs./Mft. |
| VXC162SCU | 16 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.346” | 88 lbs./Mft. |
| VXC149SCU | 14 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.620” | 313 lbs./Mft. |
| VXC148SCU | 14 AWG 7 Strands Class B | 8 Conductors | 0.060” | 0.579” | 278 lbs./Mft. |