16 AWG 19 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 2 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 2 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 30 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 37 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 3 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 3 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 4 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 4 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 5 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 5 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 6 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VXC1619SCU | 16 AWG 7 Strands Class B | 19 Conductors | 0.060” | 0.733” | 355 lbs./Mft. |
| VXC162LCU | 16 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.396” | 92 lbs./Mft. |
| VXC162SCU | 16 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.346” | 88 lbs./Mft. |
| VXC1630SCU | 16 AWG 7 Strands Class B | 30 Conductors | 0.080” | 0.940” | 668 lbs./Mft. |
| VXC1637SCU | 16 AWG 7 Strands Class B | 37 Conductors | 0.080” | 1.010” | 786 lbs./Mft. |
| VXC163LCU | 16 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.407” | 106 lbs./Mft. |
| VXC163SCU | 16 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.366” | 105 lbs./Mft. |
| VXC164LCU | 16 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.445” | 140 lbs./Mft. |
| VXC164SCU | 16 AWG 7 Strands Class B | 4 Conductors | 0.045” | 0.395” | 123 lbs./Mft. |
| VXC165LCU | 16 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.479” | 163 lbs./Mft. |
| VXC165SCU | 16 AWG 7 Strands Class B | 5 Conductors | 0.045” | 0.425” | 142 lbs./Mft. |
| VXC166LCU | 16 AWG 7 Strands Class B | 6 Conductors | 0.060” | 0.545” | 195 lbs./Mft. |