16 AWG 6 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 7 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 7 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 8 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 8 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 9 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 9 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
18 AWG 12 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
18 AWG 15 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
18 AWG 19 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
18 AWG 2 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
18 AWG 30 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VXC166SCU | 16 AWG 7 Strands Class B | 6 Conductors | 0.045” | 0.463” | 163 lbs./Mft. |
| VXC167LCU | 16 AWG 7 Strands Class B | 7 Conductors | 0.060” | 0.545” | 205 lbs./Mft. |
| VXC167SCU | 16 AWG 7 Strands Class B | 7 Conductors | 0.045” | 0.463” | 178 lbs./Mft. |
| VXC168LCU | 16 AWG 7 Strands Class B | 8 Conductors | 0.060” | 0.582” | 234 lbs./Mft. |
| VXC168SCU | 16 AWG 7 Strands Class B | 8 Conductors | 0.045” | 0.500” | 196 lbs./Mft. |
| VXC169LCU | 16 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.619” | 258 lbs./Mft. |
| VXC169SCU | 16 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.567” | 236 lbs./Mft. |
| VXC1812SCU | 18 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.574” | 226 lbs./Mft. |
| VXC1815SCU | 18 AWG 7 Strands Class B | 15 Conductors | 0.060” | 0.603” | 266 lbs./Mft. |
| VXC1819SCU | 18 AWG 7 Strands Class B | 19 Conductors | 0.060” | 0.661” | 331 lbs./Mft. |
| VXC182SCU | 18 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.320” | 75 lbs./Mft. |
| VXC1830SCU | 18 AWG 7 Strands Class B | 30 Conductors | 0.060” | 0.809” | 484 lbs./Mft. |