14 AWG 6 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 6 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 7 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 7 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 8 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 8 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 9 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 9 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 12 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications
16 AWG 12 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 152 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications
16 AWG 15 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VXC146LCU | 14 AWG 7 Strands Class B | 6 Conductors | 0.060” | 0.587” | 244 lbs./Mft. |
| VXC146SCU | 14 AWG 7 Strands Class B | 6 Conductors | 0.045” | 0.505” | 204 lbs./Mft. |
| VXC147LCU | 14 AWG 7 Strands Class B | 7 Conductors | 0.060” | 0.587” | 264 lbs./Mft. |
| VXC147SCU | 14 AWG 7 Strands Class B | 7 Conductors | 0.045” | 0.503” | 219 lbs./Mft. |
| VXC148LCU | 14 AWG 7 Strands Class B | 8 Conductors | 0.060” | 0.628” | 293 lbs./Mft. |
| VXC148SCU | 14 AWG 7 Strands Class B | 8 Conductors | 0.060” | 0.579” | 278 lbs./Mft. |
| VXC149LCU | 14 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.670” | 329 lbs./Mft. |
| VXC149SCU | 14 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.620” | 313 lbs./Mft. |
| VXC1612LCU | 16 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.682” | 321 lbs./Mft. |
| VXC1612SCU | 16 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.631” | 297 lbs./Mft. |
| VXC1615LCU | 16 AWG 7 Strands Class B | 15 Conductors | 0.060” | 0.729” | 378 lbs./Mft. |
| VXC1615SCU | 16 AWG 7 Strands Class B | 15 Conductors | 0.060” | 0.678” | 355 lbs./Mft. |