18 AWG 12 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 37 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 30 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 19 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 15 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
16 AWG 12 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 37 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 30 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 19 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 15 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 12 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
12 AWG 37 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VXC1812SCU | 18 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.574” | 226 lbs./Mft. |
| VXC1637SCU | 16 AWG 7 Strands Class B | 37 Conductors | 0.080” | 1.010” | 786 lbs./Mft. |
| VXC1630SCU | 16 AWG 7 Strands Class B | 30 Conductors | 0.080” | 0.940” | 668 lbs./Mft. |
| VXC1619SCU | 16 AWG 7 Strands Class B | 19 Conductors | 0.060” | 0.733” | 355 lbs./Mft. |
| VXC1615SCU | 16 AWG 7 Strands Class B | 15 Conductors | 0.060” | 0.678” | 355 lbs./Mft. |
| VXC1612SCU | 16 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.631” | 297 lbs./Mft. |
| VXC1437SCU | 14 AWG 7 Strands Class B | 37 Conductors | 0.080” | 1.109” | 1,096 lbs./Mft. |
| VXC1430SCU | 14 AWG 7 Strands Class B | 30 Conductors | 0.080” | 1.031” | 932 lbs./Mft. |
| VXC1419SCU | 14 AWG 7 Strands Class B | 19 Conductors | 0.060” | 0.804” | 572 lbs./Mft. |
| VXC1415SCU | 14 AWG 7 Strands Class B | 15 Conductors | 0.060” | 0.675” | 477 lbs./Mft. |
| VXC1412SCU | 14 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.741” | 415 lbs./Mft. |
| VXC1237SCU | 12 AWG 7 Strands Class B | 37 Conductors | 0.080” | 1.263” | 1,465 lbs./Mft. |