12 AWG 7 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
12 AWG 7 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
12 AWG 8 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
12 AWG 8 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
12 AWG 9 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
12 AWG 9 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 12 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 12 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 15 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 15 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 19 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
14 AWG 19 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VXC127LCU | 12 AWG 7 Strands Class B | 7 Conductors | 0.060” | 0.657” | 348 lbs./Mft. |
| VXC127SCU | 12 AWG 7 Strands Class B | 7 Conductors | 0.060” | 0.612” | 315 lbs./Mft. |
| VXC128LCU | 12 AWG 7 Strands Class B | 8 Conductors | 0.060” | 0.705” | 389 lbs./Mft. |
| VXC128SCU | 12 AWG 7 Strands Class B | 8 Conductors | 0.060” | 0.652” | 360 lbs./Mft. |
| VXC129LCU | 12 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.753” | 442 lbs/Mft |
| VXC129SCU | 12 AWG 7 Strands Class B | 9 Conductors | 0.060” | 0.697” | 405 lbs./Mft. |
| VXC1412LCU | 14 AWG 7 Strands Class B | 12 Conductors | 0.080” | 0.741” | 415 lbs./Mft. |
| VXC1412SCU | 14 AWG 7 Strands Class B | 12 Conductors | 0.060” | 0.741” | 415 lbs./Mft. |
| VXC1415LCU | 14 AWG 7 Strands Class B | 15 Conductors | 0.080” | 0.792” | 491 lbs./Mft. |
| VXC1415SCU | 14 AWG 7 Strands Class B | 15 Conductors | 0.060” | 0.675” | 477 lbs./Mft. |
| VXC1419LCU | 14 AWG 7 Strands Class B | 19 Conductors | 0.080” | 0.893” | 624 lbs/Mft |
| VXC1419SCU | 14 AWG 7 Strands Class B | 19 Conductors | 0.060” | 0.804” | 572 lbs./Mft. |