12 AWG 3 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
12 AWG 2 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
10 AWG 9 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
10 AWG 7 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
10 AWG 5 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
10 AWG 4 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
10 AWG 3 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
10 AWG 2 conductor 7 strand bare copper with XLPE insulation, a corrugated bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
18 AWG 37 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
18 AWG 30 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
18 AWG 19 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
18 AWG 15 conductor 7 strand bare copper with XLPE insulation, a helical bare copper tape shield and an overall CPE jacket 600V control tray cable, approved for use in SUN RES DIR BUR OIL RES I & II 90°C applications.
| Product | AWG Size & Stranding | Conductor Count | Jacket Thickness | Cable OD | Cable Weight |
|---|---|---|---|---|---|
| VXC123LCU | 12 AWG 7 Strands Class B | 3 Conductors | 0.045” | 0.493” | 176 lbs/Mft |
| VXC122LCU | 12 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.467” | 146 lbs./Mft. |
| VXC109LCU | 10 AWG 7 Strands Class B | 9 Conductors | 0.080” | 0.864” | 621 Lbs/Mft |
| VXC107LCU | 10 AWG 7 Strands Class B | 7 Conductors | 0.060” | 0.713” | 444 lbs./Mft. |
| VXC105LCU | 10 AWG 7 Strands Class B | 5 Conductors | 0.060” | 0.668” | 373 Lbs/Mft |
| VXC104LCU | 10 AWG 7 Strands Class B | 4 Conductors | 0.060” | 0.618” | 300 lbs./Mft. |
| VXC103LCU | 10 AWG 7 Strands Class B | 3 Conductors | 0.060” | 0.563” | 240 lbs./Mft. |
| VXC102LCU | 10 AWG 7 Strands Class B | 2 Conductors | 0.045” | 0.509” | 172 lbs./Mft. |
| VXC1837SCU | 18 AWG 7 Strands Class B | 37 Conductors | 0.080” | 0.911” | 608 lbs./Mft. |
| VXC1830SCU | 18 AWG 7 Strands Class B | 30 Conductors | 0.060” | 0.809” | 484 lbs./Mft. |
| VXC1819SCU | 18 AWG 7 Strands Class B | 19 Conductors | 0.060” | 0.661” | 331 lbs./Mft. |
| VXC1815SCU | 18 AWG 7 Strands Class B | 15 Conductors | 0.060” | 0.603” | 266 lbs./Mft. |